<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-27 16-15-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 71 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.1 kHz -21 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 19017 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,7 dBr 2,88 dBr 3,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Schiff Heinrich (Sello), Sanders Samuel (Piano) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2025/03/27 16.14.20 Total samples: 19017 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 3,9 dBr MIN: 1,7 dBr AVE: 2,88 dBr % above 12,2 dBr: 0,0 Last value: 2,7 dBr (2025/03/27 16.14.20) 16.00 16.02 16.04 16.06 16.08 16.10 16.12 16.14 -1 0 1 2 3 4 Pm [dBr]